PEMirco MULTILINK ACP Flashing S32K EVB

Hardware setting

S32K118 EVB

S32K118 EVB have to use External Power Supply(5-12V) to supply DC power

Because of use external power, J107 Jumper have to switch to Pin2 & Pin3.

Ensure the jumper configuration is correct, check jumpers J109, jumpers J109, J110 and J11 must be changed from Pin1-Pin2 to Pin2-Pin3 .

Using J14 SWD Connector to flashing S32K118


Using MULTILINK ACP PorC to flashing S32K118 EVB

If the hardware is set up correctly, the MULTILINK ACP orange light will turn on.


Software Setting

Right click project -> Debug As → Debug Configurations…

Select project -> PE micro Debugger → Interface USB Multilink→ Refresh → Debug

Initially, the Port label is empty, but after clicking the Reflash button, it will display the USB-ML-AVP RevB device.