COM

Device Node

ES2 & MP (JetPack 6.x)

We have designed 2x 3-wire RS232 + 1x isolated RS485 inside a DB9. From the software perspective:

  • COM1, RS232, maps to /dev/ttyTHS2

  • COM2, RS232, maps to /dev/ttyTHS0

  • COM3, Isolated RS485, maps to /dev/ttyTHS1

ES2 & MP (JetPack 5.x)

We have designed 2x 3-wire RS232 + 1x isolated RS485 inside a DB9. From the software perspective:

  • COM1, RS232, maps to /dev/ttyTHS3

  • COM2, RS232, maps to /dev/ttyTHS0

  • COM3, Isolated RS485, maps to /dev/ttyTHS1

ES1

We have designed 2x 3-wire RS232 + 1x isolated RS485 inside a DB9. From the software perspective:

  • COM1, RS232, maps to /dev/ttyTHS1

  • COM2, RS232, maps to /dev/ttyTHS0

  • COM3, Isolated RS485, maps to /dev/ttyAMA0

Using DB9 Directly

Pin Out (NRU-220S Panel)
COM1
COM2
COM3

1

2

RX

3

TX

4

TX

5

GND

GND

6

RX

7

DATA-

8

DATA+

9

[EOL] Using the 1-to-3 Y-Cable from Neousys

The old 1-to-3 Y-cable currently is no longer available (393-D1131150-034)

The pin out is as follows.

Pin Out (Each Splitter)
Splitter A (COM1)
Splitter B (COM2)
Splitter C (COM3)

1

2

RX

RX

DATA+

3

TX

TX

DATA-

4

5

GND

GND

6

7

8

9

Disable Flow Control

We don't use the flow control of Jetson. Please disable hardware and software flow control.

Last updated